Ceiling Fan and Fixture Support
MODEL 01100
The Saf-T-Brace
®
easily installs through a 4" diameter hole in the ceiling. It is U.L. listed for fan support and
exceeds the requirements of the National Electric Code for fans weighing up to 70 lbs., for lighting fixtures
mounted on 16” center joists weighing up to 150 lbs., and lighting fixtures mounted on 24” center joists
weighing up to 50 lbs.
INSTALLATION INSTRUCTIONS
Turn off electrical power at breaker!
If there is not a hole where you want to hang the fan, cut a hole in the sheetrock using the electrical box provided as a
template. If no electricity is available, a swag kit or wire cover may be used.
1. Clear the installation area of insulation, wiring and existing lightweight bar hanger. Remove wire attached to the side of
the joist where Saf-T-Brace
®
will attach. Insert Saf-T-Brace
®
through the sheetrock and onto the ceiling, centering square
tube over the hole in the sheetrock (figure 1).
2. With both Saf-T-Brace
®
feet resting on the sheetrock, by hand only rotate the square tube until “teeth” are firmly locked
into the joist; a
7
8" wrench may be required for the final turn to bring bar around to the flat side. Do not install using
wrench. A flat side of tubing must be parallel to the sheetrock so that the box bracket will hang correctly (figure 2).
3. Snap the bracket over the square tube and center it over the hole (figure 3). Make sure the screws are pointed toward the
hole in the sheetrock (figure 4).
4. Remove one knockout from electrical box and install connector. Pull the wire down through the hole and into the
connector. Insert the electrical box into the hole and onto the bolts of the bracket (figure 5). Secure the box with the two
nylon locknuts provided, tighten securely (figure 6).
Do not overtighten.
5. When you are ready to hang the fan or fixture, remove Saf-T-Cap
®
. Install fan or fixture screwing the 10-24 x
3
4" bolts
into the threaded inserts, NOT THE ELECTRICAL BOX EARS! Box ears can be used to mount lightweight fixtures or cover
plates. Finish installation according to fan or fixture manufacturer’s instructions.
figure 6
figure 5
figure 4
figure 3
figure 2
figure 1
Westinghouse Lighting Corporation
Philadelphia, PA 19154-1029, U.S.A.
Westinghouse Lighting Corporation,
a Westinghouse Electric Corporation licensee
“Westinghouse” and “You can be sure. . . if it’s Westinghouse”
are all registered trademarks of Westinghouse Electric Corporation
© 2012 WESTINGHOUSE LIGHTING CORP.
Vue de la page 0
1 2 3

Résumé du contenu

Page 1 - MODEL 01100

Ceiling Fan and Fixture SupportMODEL 01100The Saf-T-Brace® easily installs through a 4" diameter hole in the ceiling. It is U.L. listed for fan s

Page 2 - MODELO 01100

Soporte para Abanicos de Techo y Accessorios de IluminaciónMODELO 01100La Saf-T-Brace® se instala fácilmente a través de un agujero de 4 pulg. (10,16

Page 3 - MODELE 01100

Soutien du Ventilateur de Plafond et de l’Appareil d’ÉclairageMODELE 01100L’armature de sécurité Saf-T-Brace® s’installe facilement dans une ouverture

Commentaires sur ces manuels

Pas de commentaire